EIKI Movement Sensor A-3 User Manual

Page of 4
 
Eiki A-3 Movement Sensor manual.                                                             Page 3 
Wiring 
Connect the terminals as shown in the 
diagram to the control panel or access 
port. 
You do not need to connect the tamper 
switch terminals. 
 
Option Links 
For the purpose of detecting room 
occupancy, we are not as concerned 
about false alarms as we would be if 
this were a security system. In fact, 
not detecting room movement (when 
people are in the room) would be more 
of a problem.  
For this reason, Long Range and 
Short Pulse Count links should be 
fitted. Similarly, having the LED 
activate is a benefit.  
So for our application, fit all 3 links. 
Testing 
With the cover fitted, apply power and wait at 
least 30 seconds. After this time, if there is 
no movement, the LED should go out. Once 
this has happened, any movement should 
cause a couple of rapid flickers and the LED 
should lock on for about 5 seconds. 
Walk around the room and check that your 
movement can be reliably detected. If range 
seems to be inadequate, check the position of 
the PCB in the base. A higher position lowers 
the angle of the detection beam. 
 
Programming your control panel 
to recognise the A-3 and perform 
actions 
In Eiki Control System editor, select Device 
Options
 under the Handset menu. 
The Inactivity Timeout option allows you to 
choose the number of seconds (up to 14400 
seconds which is 240 minutes) after either 
the last key is pressed or the A-3 sensor 
detects movement. When that time expires 
with no movement detected or key pressed, 
the actions you choose under Edit Actions will 
occur. 
After you have selected the time, click Edit 
Actions. You can treat this just like the 
programming of any other key. 
For more information 
Please refer to the control panel’s manual for 
more information. 
Alarm    +   -
 N/C       12v
GND
+12v
Sensor
Option links 
Tamper switch