Edge Products ES3528-WDM User Manual

Page of 556
Line Commands
19-19
19
Line Commands
You can access the onboard configuration program by attaching a VT100 
compatible device to the server’s serial port. These commands are used to set 
communication parameters for the serial port or Telnet (i.e., a virtual terminal).
line
This command identifies a specific line for configuration, and to process subsequent 
line configuration commands.
Syntax 
line {console | vty}
• console - Console terminal line. 
• vty - Virtual terminal for remote console access (i.e., Telnet). 
Default Setting 
There is no default line.
Command Mode 
Global Configuration 
Table 19-8   Line Commands
Command
Function
Mode
Page
line 
Identifies a specific line for configuration and starts the line 
configuration mode
GC
login 
Enables password checking at login 
LC
password 
Specifies a password on a line
LC
timeout login 
response
Sets the interval that the system waits for a login attempt
LC
exec-timeout 
Sets the interval that the command interpreter waits until user 
input is detected
LC
password-thresh
Sets the password intrusion threshold, which limits the number of 
failed logon attempts 
LC
silent-time
*
* These commands only apply to the serial port.
Sets the amount of time the management console is inaccessible 
after the number of unsuccessful logon attempts exceeds the 
threshold set by the password-thresh command
LC
databits
Sets the number of data bits per character that are interpreted and 
generated by hardware
LC
Defines the generation of a parity bit
LC
speed
Sets the terminal baud rate
LC
stopbits
Sets the number of the stop bits transmitted per byte 
LC
disconnect 
Terminates a line connection 
PE
show line 
Displays a terminal line's parameters
NE, PE