Cuno SQC Pro User Manual

Page of 15
E.  MOUNT THE FAUCET
Undercounter installations generally require that the
faucet's built-in air gap be used.  In basement installations, the
built-in air gap does not have to be used if one is provided
elsewhere on the drain line.
For Basement Installations Without An Air Gap Module
See Installation Instructions O.
IMPORTANT: 
The Uniform Plumbing Code dictates that there
must be an air gap between the RO reject line and the waste
drain.  An optional non-air gap faucet, which requires a smaller
9/16" mounting hole, is available to make basement installa-
tions easier.
Undercounter Installation With An Air Gap Faucet:
1)
Familiarize yourself with all of the components shown in 
the air gap faucet diagram. (See Fig. 2)
2)
Remove the hardware from the threaded nipple of the 
faucet, except for the chrome base plate and the rubber 
washer.  The rubber washer may be replaced with a bead of 
plumber's putty for a neater appearance.
3)
Connect the 1/4" green tubing supplied in the installation 
kit to the smaller barb on the air gap faucet.  Push it on 
firmly until it seats.
4)
Connect the 3/8" black tubing to the larger barb on the air 
gap faucet.  Push it on firmly until it seats.
5)
From above the sink counter-top, feed the air gap tubing 
and the threaded nipple through the faucet mounting hole 
and position the faucet spout over the sink.
6)
From below the sink/countertop, install the white spacer 
(open side toward the air gap tubing), flat washer and hex 
nut onto the threaded nipple and tighten it by hand.
7)
Back off on the hex nut just enough to slide the slotted 
washer (open side toward the air gap tubes) between the 
white spacer and the underside of the sink/countertop.
8)
After rechecking the faucet orientation, tighten the hex nut 
with a 9/16" wrench until the faucet feels secure.
9)
From above the sink, make any minor orientation corrections 
by turning the faucet on its flats with a padded adjustable 
wrench.  Use care so as not to mar the chrome finish.
5
Faucet with Air Gap
Faucet without Air Gap
Side View
Back View
Side View
Chrome base plate
Air Gap hole
1/4” Standard 
green tubing
Special red “SFC”
tube from RO
Black 3/8” Reject 
tubing to drain
Blue 3/8” Product 
water tubing
Blue 3/8” Product 
water tubing
Rubber washer
Plastic bottom washer
Threaded nipple
Flat washer
Star washer
Hex nut
Blue 3/8” Product 
water tubing
Chrome base plate
Rubber washer
Threaded nipple
Flat washer
Spacer
Hex nut
Slotted washer
Fig. 2