3.3 Diagnostics, 
Checking 
          Program Number 
The diagnostic facility checks the ROM, 
RAM, SIO and displays program ID. 
1.  Press the [MENU] key to open the 
menu. 
2.  Select SYSTEM MENU2 and press the 
[ENT] key. 
SYSTEM MENU2
TEST
DIMMER            INTERNAL
/LANG.   ENGLISH
            
 
3.  Press the [ENT] key. The following 
display appears. 
TEST START ?
(STOP: PWR OFF)
ARE YOU SURE ?
YES
         NO
 
4.  Press the [ENT] key to start the test. In 
a few moments the display should 
changes as shown at the top of the 
adjacent column. 
The ROM, RAM and SIO (if special 
connector is used) are checked for 
proper operation and the results shown 
as OK or NG (No Good). For NG, 
contact your dealer for advice. 
The program number also appears 
here. 
“PUSH KEY” is highlighted, prompting 
you to check the controls. Operate any 
control (except the [POWER] switch) 
within five seconds. The name of the 
activated control appears on screen if it 
is operating normally. Note that if no 
control is operated within five seconds, 
the equipment automatically begins 
checking the LCD. 
   
TEST
ROM
:  OK  12.3CX
RAM
:  OK
SIO
:  OK             
PUSH KEY
(STOP: PWR OFF)
6550100003I
6550110003J
CNT: 006
6550120003K
No. of times test
consecutively
executed.
Name of control operated
appears here.
6550100003I = Display Unit DS-800
6550110003J = Distribution Box DS-801
6550120003K = Transceiver Unit DS-810
Transducer temperature
X appears when
temperature
sensor is
abnormal
 
    Control operated and indication 
Control Indication 
 
UP 
 
DOWN 
   
LEFT 
 
RIGHT 
MENU MENU 
ENT ENT 
DISP DISP 
DIM DIM 
* * 
5.  The equipment automatically checks 
the LCD, displaying the following in 
order. 
<LCD CHECK>
ALL ON 2 SEC.
ALL OFF 3 SEC.
 
6.  The test repeats itself. To stop the test, 
turn the power switch off and on again.