Furuno DOPPLER SPEED LOG DS-80 User Manual

Page of 40
 
 
SP - 1
 
SPECIFICATIONS OF THE DOPPLER SPEED LOG 
DS-80 
 
1. GENERAL 
(1)  Speed Range 
Fore-Aft: -10.0 to +40 knots through-the-water 
(2)  Distance Run 
0.00 to 999,999.99 nautical miles through-the-water 
(3)  Working Depth 
Water depth greater than 3 m beneath the keel. 
(4)  Working Frequency 
1.0 MHz 
(5)  Speed Accuracy 
1.0% or 0.1 knots whichever is the greater 
(6)  Distance Accuracy 
1.0% or 0.1 nm whichever is the greater 
Note: Accuracy is subject to shallow water effects, to the effect of wind, current and tide, and 
sensor location. Any ultrasonic equipment having the same frequency may interfere with 
speed measurement. The Doppler Log transducer should be installed apart from the 
transducers of such kind of equipment. 
 
2. DISPLAY UNIT 
(1)  Display 
Character size 15 or 21 mm H on monochrome LCD 
(2) Indication 
Ship’s speed 
Fore: 
c**.* knots (+40.0 kt max.) 
  
Aft: 
d**.* knots (-10.0 kt max.)   
Distance run 
******.** nm 
(3)  Other Function 
Diagnostic check 
 
3. DIGITAL INTERFACE 
(1) Serial 
Signal 
Output: 
2 ports; VBW, VLW in IEC 61162-1 (NMEA 0183 Ver 2.0) 
Input: 
1 port; IEC 61162 (NMEA 0183 Ver 2.0) 
(2)  Analog Signal 
Speed signal for Analog display: 2 port 
   
 
-3.3 mA to 10 mA/ -10 kt to +30 kt 
 
Analog current output: 1 port 
 
 
4 mA to 20 mA/ -10 kt to 30 kt 
 
Analog voltage output: 1 port 
 
 
-3.3 V to 10 V/ -10 kt to 30 kt 
(3)  Distance run output 
2 ports; Contact closure each 0.005 nm, forward speed, 
   
30 VDC: 0.4 A   
(4)  System Check signal 
1 port, 30 VDC: 0.2 A, default: closed