Furuno SC-120 User Manual

Page of 96
3. OPERATION 
 
 
 
3-18
3.11 OTHERS 
Menu 
The OTHERS menu chooses whether to output last-used heading data, and 
smooths rate of turn (rate-of-turn meter required). 
 
1.  Press the [MENU] key to display the main menu. 
MAIN MENU
SATELLITE
DGPS
I/O SETUP
INST MENU
ERASE
TRIP MENU
ALARMS
MESSAGES
GPS SETUP
SYS SETUP
SOFT VER.
OTHERS
 
Main menu 
3.  Choose OTHERS and press the [ENT] key. 
OTHERS
 
HOLD HDG DATA: 
OFF
      
SMOOTH ROT  : 2.5SEC
ROT RANGE     : 
60
°/min
 
Others menu 
4.  Choose HOLD HDG DATA and press the [ENT] key. 
5.  Choose ON to use, at power on, last-used heading until current heading is 
calculated. Last-used heading flashes to inform that it is unreliable. 
6.  Press the [ENT] key. 
7.  Choose SMOOTH ROT and press the [ENT] key. 
8.  Use the Omnipad to enter smoothing time. Choose location with ◄ or ►; 
change value with ▲ or ▼. 
9.  Press the [ENT] key. 
10. Choose ROT RANGE and press the [ENT] key. 
11. Choose the range of the ROT graph: 30, 60 or 90 and press the [ENT] key. 
12. Press the [DISP] key to close the menu.