Fujitsu MAN3367 User Manual

Page of 302
C141-E124-01EN
5 - 17
Table 5.3
Sense data error classification  (2 of 4)
K*
C*
Q*
Outline of Error
L*
Recovery Method
(See Table 4.4.)
31
00
Medium form   at corrupted
Need
18
FORMAT command failed
3
31
01
The data format on the disk media is not correct.
4
03
xx
Peripheral device write fault
Need
7
32
01
Defect list update failure
These are errors detected in the operation of the
disk drive.
4
15
xx
Positioning error
Need
12
This is an error of the disk drive's seek system.
4
32
00
No defect spare location available
None
19
No usable alternate blocks exist on the disk drive.
4
40
nn
Diagnostic failure on component 'nn'
Need
13
An error was detected in the IDD's self-diagnosis.
4
44
nn
Internal target failure
Need
20
An internal hardware error or a microcode
detection error was detected in the IDD.
4
4C
xx
Calibration failed
Need
10
C4
xx
Drive failure
The initial seek was terminated abnormally.  Or, a
serious error was detected in the drive's control
system.
5
20
00
Invalid command operation code
None
2
21
00
Logical block address out of range
24
00
Invalid field in CDB
25
00
Logical unit not supported
26
00
Invalid field in parameter list
There is an error in the command specification
contents.
5
3D
00
Invalid bits in IDENTIFY message
None
3
90
00
Initiator's SCSI ID not identified
An error was detected in the SCSI protocol in the
command execution sequence.
6
29
xx
Power on, reset, or BUS DEVICE RESET occurred
None
14
The IDD was initialized by a Power on, RESET
condition or BUS DEVICE RESET  message.
K: Sense Key
C: Sense Code
Q: Sub-sense code
L: Logging Necessary?  (shown in Section 5.2.3)