Cooper Bussmann 858 User Manual

Page of 63
 
DOCUMENT 1025  
REV. B 
Instruction Manual  
 AGS-LED 
 858 LED Series 
Sizes 1, 2, 3, 4 and 5 
 
 
 
 
 
PROBLEM 
POSSIBLE CAUSE 
CORRECTIVE ACTION 
(P.2) Sign will 
not light  
Input current is below or exceeds 
specification. (Input current is 
specified between 2.8 and 6.6 
amps using a true RMS Ammeter.  
L858 Power Supply indicator RED 
LEDs D4 is ON, and D7 is OFF; 
Table 12) 
Adjust CCR current (See 
Tables 9-11 and/or replace 
isolation transformer with 
appropriate wattage for sign 
(see Tables 3-8). 
(P.3) Sign will 
not light  
Optional ON/OFF switch in OFF 
position  
Turn switch to ON position. 
(P.4) Sign will 
not light  
Power Supply Circuit Card +15V 
supply failed (See Table 12) 
Verify Green LED D29 is lit.  
Replace Power Supply Board 
if D29 is not lit.(Section 10.12)  
(P.5) Sign will 
not light  
Power Supply Circuit Card +3.3V 
supply failed (See Table 12) 
Verify Green LED D11 is lit.  
Replace Power Supply Board 
if D11 is not lit (section 
10.12). 
(P.6) Sign will 
not light  
Loose/broken wire(s)/missing 
connections 
Verify Power Supply 
connections match Power 
Supply Wiring Diagram 
(Figures 18 & 21). 
(P.7) Sign will 
not light  
Output Electrical Open Circuit 
(See Table 12) 
Verify LED cable connectors 
are properly seated in their 
respective receptacles; reseat if 
necessary (See Sections 10.5 & 
10.6) 
(P.8) Sign will 
not light  
LED MODULE(s) mounted/wired 
incorrectly 
Verify that LED MODULES 
are mounted and wired 
according to LED Array 
Wiring Diagram. (See Figures 
7-11 and Sections 10.7-10.9)  
 
(P.9) Sign will 
not light  
LED MODULE(s) open circuit 
failure (Assumes P.7 Action taken) 
Replace suspected open circuit 
LED MODULE with spare 
known good LED