Contemporary Research IP-HDVR User Manual

Page of 38
Contemporary 
Research    29 
 
 
      
IP-HDVR HD Tuner-DVR
 
Ethernet and RS-232 Protocol 
Response Strings 
 
Typical: [Attention] [Unit#] [data ...data] [cr] [lf] 
 
IP-HDVR status response strings contain ASCII characters similar to those used for the same functions in 
command strings. An ASCII 'carriage return' and ‘line feed' follow each response string. Functions shown as 
NA are not applicable or available in the IP-HDVR; characters will appear in status strings as lower-case x.  
 
Channel/Source Status Response String (T): 
 
Start # CMD Power  Major 
Channel 
Video  
Mute 
Input RF 
NA 
Minor 
Channel 
NA Function 
 1-9   U=On 
M=Off 
3 digits 
Un- 
muted 
0=Channel 
1=AV1 
2=AV2 
 
A=Air  
C=Cable 
 3 
digits  0=None 
1=Play 
2=Stop  
3=Pause 
4=FFwd 
5=Rew 
8=Rec 
9=TimeShift 
T U 032 U 
A x 
002 
 
For compatibility with 232-series tuners, 232-ATSC (XXX-XX) channels are split into Channel 1 (Major) and 
Channel 2 (Minor) sections.  
 
Audio Status Response String (V): 
 
Start 
Unit 
CMD 
Power 
Volume 1 
Volume Mute 
Stereo 
Volume 2 
 1-9   U=On 
M=Off 
0-63 
Emulated 
level 
2 digits 
U=Unmuted 
M=Mute 
N/A 0-100 
Actual level 
3 digits 
< 1 V  U 
63 
100 
 
Volume 1 emulates 232-series volume level for compatibility with existing applications. 
Volume 2 shows actual IP-HDVR level, from 0-100 steps. 
 
Front Panel Mode Status Response String (S): 
 
Start Unit CMD  Audio  Tune 
 
Mode 
Lockout Bass Treble Output  Ratio 
Current 
Ratio 
Mode 
NA 
 1-9   N/A  N/A 
1 digit 
0-9 Fixed 
2 digits 
Fixed 0=RGB 
1=DVI 
2=YPbPr 
3=Video 
0-3 
0=1080i 
1=720p 
2=480p 
3=480i 
1-7* 4 
digits 
< 1 S  x 
08  4 
6  xxxx 
 
Current Ratio is the actual output ratio; Ratio Mode is the selected mode (see chart on page 9) 
 
Q Mode Response String (Q): 
 
Start 
Unit 
CMD 
Q0 Q1  Q2  Q3 Q4  Q5  N/A 
  1-9    N/A N/A  N/A  N/A N/A 
IR 
0=Off 
A=Normal 
digits 
Q x x  x  x x  A xxxx