Installation Instructions 
 
 
 
Illustration 2 
 
ELECTRICAL OUTLET LOCATION   
Outlet should NOT be in the shaded area as indicated 
on Illustration 2 
NOTE 1: 
If the Depth (C) dimension is greater than 21” (53.3 cm), 
the outlet location may be in any area on the rear wall.  
NOTE 2: 
The floor of the opening should be constructed of 
plywood strong enough to support the weight of the 
oven and floor load (approximately 100 pounds). The 
floor should be level for proper operation of the oven. Be 
sure to check the local building code as it may require 
that the opening be enclosed with side, ceiling and rear 
partition. The proper functioning of the oven does not 
require the enclosure. 
 
Flanges 
Screw A 
Exhaust Dust 
Assembly 
Screw A 
 
Illustration 3 
 
EXHAUST DUCT ASSEMBLY 
 
1.  Place the Exhaust Duct in the opening. When 
the Exhaust Duct Assembly is in the opening 
correctly, the flanges will be tightly against the 
lower edge of the opening. See Illustration 3.  
 
2.   Secure the Exhaust Duct Assembly with the 
two screws A. 
 
IMPORTANT: Secure screws in outer hole.