Compatible Systems 1220I User Manual

Page of 45
Chapter 6 - Basic Configuration Guide
27
SMDS Configuration
This section covers the settings required for SMDS (Switched
Multi-megabit Data Service) operation of the MicroRouter 1220i WAN
0 interface (IP only). SMDS is a connectionless, packet-switched
service that offers LAN-to-LAN connectivity across a wide area at up to
1.544 Mbps.
v
Note:
The IP protocol settings and the physical communication
settings are the same as they would be for Frame Relay operation. The
only parameters which should be set differently for SMDS are the Link
Configuration and the SMDS addressing section.
Link Configuration
SMDS is presently supported in the MicroRouter only via dedicated
line operation.
Set Dedicated connection
Set SMDS connection
CV: Use the Link Configuration: WAN Dialog Box.
TB:
Use configure and then set the Mode and ConnectMode
keywords in the Link Config WAN 0 (and/or WAN 1) section.
SMDS Addressing
Many of these parameters will be given to you by your service provider.
CV: Use the Link Configuration: WAN Dialog Box and select SMDS
from the Link Type pull-down menu. Then click on the SMDS
button to set addresses.
TB: Use configure and set the StationAddressIPMulticast and
PollingFrequency keywords in the SMDS WAN 0 (and/or
WAN 1) section.
Saving a Configuration File to Flash ROM
Once a configuration is complete, you can save it to the router’s Flash
ROM. Until saved, all changes are made in a separate buffer and the
actual router interfaces run as before the changes were made.
CV: Use the Save to/Device option from the File menu.
TB: Use the save command.