Location Recorder  Model PD606
Chapter 8: MENU mode/SYS SETUP menu
The "Stereo out level" menu item selects the nominal output level of the stereo bus.
According to the device connected to the [ST BUS OUT] connector, select the level appropri-
ately.
ST BUS OUT nominal level setting [Stereo out level]
1)
While the unit is stopped, press the [SHIFT] key to light the SHIFT indicator, followed by the
[ENTER/YES] key.
2)
While “SYS SETUP” is highlighted, press the [ENTER/YES] key.
The display now shows the SYS SETUP menu screen.
Selectable between “+4dBu”, “-10dBu” and “-60dBu” (the default is “+4dBu”).
Options
5)
Press the [EXIT] key repeatedly until you exit the MENU mode.
Flashing
4)
Use the [MENU] dial to select the desired option and press the [ENTER/YES] key to confirm
your setting.
3)
Use the [MENU] dial to select the “Stereo out level” menu item and press the [ENTER/YES]
key.
The current setting starts flashing and you can now select the desired option.