Fostex PD606 User Manual

Page of 226
195
Location Recorder  Model PD606
Chapter 8: MENU mode/TC SETUP menu
Using the "TC PWR Time" item, you can set the time until the TC generator turns off after
turning off the main unit.
It is set to five minutes by default, so after the PD606 is turned off, the internal TC generator
continues working for five more minutes.
Internal TC generator power-off timer [TC PWR Timer]
Flashing
<Note>: 
When any option except "0min" is selected, the display backlight flashes
weakly and slowly after turning off the PD606, indicating that the internal TC gen-
erator is still working. We recommend selecting shorter time for the "TC PWR Timer"
item when operating the unit on battery.
4)
Press the [EXIT] key repeatedly until you exit the MENU mode.
3)
Use the [MENU] dial to select the desired option, and press the [ENTER/YES] key to confirm
your setting.
1)
When the unit is stopped, press the [SHIFT] key to light the [SHIFT] indicator, followed by the
[TIME/TC SET] key.
The display now shows the TC SETUP menu screen.
2)
Use the [MENU] dial to select the “RecIn via ExtTC” menu item, and press the [ENTER/YES] key.
The current setting starts flashing and you can now select the desired option.
You can select from among “0min”, “5min”, “10min”, “15min”, “30min”, “1hour”, “2hour”, “4hour”,
“8hour” and “Cont.” (Continue) (the default is “5min”).
Options