Fostex PD606 User Manual

Page of 226
43
Location Recorder  Model PD606
Chapter 3: Names and Functions
5.
[WORD IN] termination switch
Terminates the word input signal by setting the switch to "ON".
6.
[WORD/VIDEO IN] and [WORD OUT] connectors (BNC type)
The [WORD/VIDEO IN] connector receives word or video clock. It automatically
detects the clock type (word or video).
The [WORD OUT] connector feeds a word clock.
7.
[DIGITAL I/O] connector (D-sub 25-pin/female)
Receives and feeds AES/EBU or S/P DIF digital signals.
It automatically detects the digital audio input format (AES/EBU or S/P DIF).
You can set the digital input channels in the SETUP menu.
Signal
Input 1/2
Input 3/4
Input 5/6
Input 7/8
Output 1/2
Output 3/4
Output 5/6
Output 7/8
Frame GND
Open
Hot
Cold
1
2
3
4
5
6
7
8
14
15
16
17
18
19
20
21
10, 12, 13, 22,
23, 24, 25
9, 11
Terminal
treatment
Open
GND
• The pin assignment is compatible with the 25-pin D-sub connectors provided on
the Fostex 8350 and Yamaha equipment.
• Recommended connection cable:
DBK-258, DB-25 (M), TO 4XLR (M), AND 4XLR (F), 5M (16.5FT.), AES/EBU DIGITAL
AUDIO TRANSFER CABLE  HOSA TECHNOLOGY,INC.
8.
Angle adjustment arm
1
14
13
25
10.
[PARALLEL] connector (MINI DIN 8-pin)
This connector accepts parallel remote signals for controlling the PD606 externally.
You can control the following nine operations remotely.
1
2
3
4
5
6
7
8
9
PLAY
STOP
RECORD
REWIND
F. FORWARD
CUE point registration
PAUSE
FILE
 
FILE
 
9.
[9P-REMOTE] connector (D-sub 9-pin/female)
Not currently supported. Prepared for the future expansion.