Foxconn Interfacility Link 7870 User Manual

Page of 54
3.3 7870 Interfacility Link Pinouts
page 20
Document no. 93-005-35-C5
3.3
7870 Interfacility Link Pinouts
3.3.1
Transmitter Pinout
Note
If a 2380 Relay Adapter is installed RF and Optical Levels are measured 
together; the alarm indicates a problem in either the RF or Optical Levels.
Figure 15 7870T Transmitter pinout
Standalone 
9-Pin
Connector 
[J13]
7180M
Chassis 
Backplane
Connector
2380 Relay 
Adapter
Connector
Name
Description
1
+14V Power
200 mA [max 
≥ 10°C]
1
2
Spare
Not Used
3
J11-P9, J12-P25
J13-P25
J4-P25
GND
Chassis Ground
4
J13-P1 to J13-P8
J4-P1 to J4-P8
RSSI
RF signal strength indicator: 
range 0.2 - 10 V
5
J13-P9 to 
J13-P16
J4-P9 to J4-P16
PDI
Indicates laser optical power: 
range -4.2 to 4.8
6
J13-P17 to 
J13-P24
J4-P17 to J4-P24
LSRI
Indicates Laser Bias;
Range 
7
J12-P1 to J12-P8
J2: P1-P2
P3-P4, P5-P6
P7-P8, P9-P10
P11-P12, P13-
P14
P15-P16
RFA
RF Alarm: Open collector 
interface.
2
 Sinks current when 
RF level is low, up to 30 mA.
8
J12-P9  to 
J12-P16
See note below
OPTA
Optical Alarm: Open Collector 
Interface
. Sinks current at low 
optical, up to 30 mA.
9
J11-P1 to J11-P6
Spare
Not used
Table 4 7870T Transmitter Pinout
1.
300 ma below 10°C
2.
If the 2380 Relay Adapter is installed, the alarms are dry contact. Se Appendix 3 The 2380