Foxconn Interfacility Link 7870 User Manual

Page of 54
7870 Interfacility Link Installation and User’s Guide 
  page 27
Foxcom proprietary information
Appendix 1 Cleaning Fiber Optic Connections
The unit has an FC/APC angle polished optical connector for very high optical return loss 
performance. The units are specified into single mode fiber i.e. 9/125 micron core diameter. 
Full performance is specified only for low return loss optical plant - meaning that the fiber 
must be fusion spliced and all connections or splices must have a return loss greater than -60 
dB. With these guidelines in mind, link lengths beyond 20 kilometers (DFB based products) 
can be achieved with high performance. Specific performance and/or design assistance is 
available by request from Foxcom.
If there is low/no signal or noisy signal at a Foxcom module, the connector should be cleaned. 
Dirt on the inside connector tip can impair the flow of light causing problems in signal 
transmission. Foxcom modules are sealed but dirt can occasionally enter during installation 
and alignment. 
The input and output optical ports of all Foxcom equipment are known in the fiber optic 
world as bulkhead ports. Foxcom uses
FC/APC connectors.
The following materials are representative of the types of cleaning materials that should be 
used for cleaning the fiber optic ports and connectors. They are available from several 
suppliers. 
Wiping clothes should be made of lint free alcohol free nonabrasive materials. Swabs should 
have a tightly wrapped tip and be talcum- free. For removing dust from receptacles, a 
canned compressed gas is recommended. Do not use commercial compressed air because of 
risk of contamination. 
Description
Manufacturer
Kim wipes
Kimberly Clark
Cletop Automatic Connector Cleaner
Cletop
fiber optic Swab
Cletop or FIS
fiber optic Compressed Air
Chemtronics
Table 10
Cleaning materials