Fluke Digital Camera 1526 User Manual

Page of 41
Fluke  1520
Users Manual
8
Display
Table 2 and Figure 2 describe the display.
Table 2. Display Description
1
Voltage applied to the probes in Insulation Resistance function.
2
Low Resistance/Resistance function indicator.
3
Resistance reading held from the last measurement in Insulation Resistance or Low
Resistance function.
4
Beeper symbol shows if beeper function is turned on in Resistance function.
5
Zero symbol is on if test leads are zeroed out.
6
Main reading display for all functions.
7
Analog bar graph displays resistance on a logarithmic scale and voltage on a linear
scale. The value always tracks the main reading.
8
High voltage warning symbol flashes if voltage 
 30 V ac or dc is present on the probes.
9
Battery life indicator. Displays briefly when the Meter is first switched to a function.
Displays the amount of battery voltage left in increments of 25 %.
10
Lock symbol is on if the TEST mode is locked in Insulation or Low Resistance functions.