24
Testing and Replacing the Fuse
W
 Warning
To avoid electric shock, disconnect the test leads from the inputs before
opening the Meter for fuse replacement.
To prevent personal injury or damage to the Meter, install ONLY Fluke
specified fuse identified in the “Replacement Parts and Optional
Accessories” section.
Before replacing the fuse, test it as described in the next section.
Testing the Fuse
Use the following procedure to test the internal fuse of the Meter.
1. 
Turn the rotary switch to the Lo 
e
 Function.
2. 
Connect the test leads to the input terminals and short them
together. Press TEST.
3. 
The display should indicate approximately 0.5 
Ω
. If the
display reads >40 
Ω
, replace the fuse as described next and
test again.
acf06f.eps