Finalizing the Installation
Travis Industries
4040708
1 0 0 - 0 1 1 6 0
8
Turn the flame adjust knob to its highest position - the flames should be approximately 10" tall.  Check
the flame on low position.  The flames should burn off of each burner hole.  If the heater does not work
correctly, contact your dealer for a remedy.
FINE TUNING THE EMBER-FYRE™  BURNER
Each installation is affected by altitude, vent configuration, and fuel quality.  Because of this, the restrictor and air
shutter may need to be fine tuned to each installation.  Follow the hints below to fine-tune the burner for
optimum performance and aesthetics.
Restrictor Hints:
Set the restrictor to the position suggested in the vent configuration table (see pages 20-23).  Turn the heater
on and allow it to reach full temperature (15 min.).  If the flames indicate there is excessive draft due to altitude or
climate, you may wish to adjust the restrictor to a more restrictive position (higher number).  Active, flickering
short flames are an indication of excessive draft.  If the flames lift off of the burner holes, this indicates not
enough draft (restrictor is set too high).  After adjustments are made the unit must be cooled down to room
temperature and restarted to make sure that the restriction is not so severe that the pilot will drop out when it is
restarted.  If the pilot does drop out reduce the restriction until it will operate continuously.
Air Shutter Hints:
 
For more glow, open the air shutter, however, this will make the flames more blue.
 
For yellow flames, close the air shutter, however, this may create less glow.
The flames should burn right 
off the top of the burner ports 
(if they are too blue, adjust 
the air control).
Lifting flames indicate 
insufficient draft (restrictor 
is set too high).
Burner
Burner Ports 
(holes)
Ghosting flames indicate 
insufficient air (restrictor set too 
high, air shutter shut down, or 
other venting error).
Lifting Flames
Correct Flames
A
A
A
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AAA
AAA
AAA
AAA
A
A
A
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AAA
AAA
AAA
Ghosting Flames
Flickering Flames
Flickering, short flames 
indicate excessive draft 
(move air shutter to a higher 
position).
Warning:    If the vent configuration is installed incorrectly the vent may cause the flames inside the heater to lift or
“ghost” – a dangerous situation.  Inspect the flames after installation to insure proper performance.  If the
vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the heater and contact
the dealer for information on remedying the problem.
9
Give this manual to the home owner and fully explain the operation of this heater.