FIC M295 User Manual

Page of 175
 
Software Functional Overview 
Controller 
 (QR_EC) 
#2 EC_DA
TA 
Query value to 
host 
Interrupt on 
OBF=1 
 
 
3.8.2  PMU08 EC RAM List 
The micro controller PMU08 acts as a supplement for power management control. It supports 
the following functions via SMBus Command 
( 0x80 , 0xC0 )
 
 
Register 
Bit Number 
Function  Address 
Name 
R/W 
7  6  5
4
3
2
1
0
Logic Default Description 
00h 
*3 
Power unit 
R(/W)  
DATA[15:0] *1 
0xffff 
0x0000: mWh     [Fixed value] 
0xffff: Unknown 
02h 
*3 
Design 
capacity 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
04h 
*3 
Last Full 
Charge 
Capacity 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
06h 
*3 
Battery 
Technology 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000 : Primary 
0x0001: Secondary [Fixed value] 
0xffff: Unknown. 
08h 
*3 
Design 
Voltage 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mV) 
0xffff: Unknown  
0Ah 
*3 
Design 
capacity of 
Warning 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
0Ch 
*3 
Design 
capacity of 
Low 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
0Eh 
*3 
Battery 
capacity 
Granularity 1
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
10h 
*3 
Battery 
capacity 
Granularity 2
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
12h 
*3 
Model 
number 
R(/W) 
DATA[15:0] *1 
0xffff  0x0000 [Not support] 
14h 
*3 
Serial 
Number 
R(/W) 
DATA[15:0] *1 
0xffff  0x0000 [Not support] 
16h 
*3 
Battery type  R(/W) 
DATA[15:8] 
*1 
All bits are 0
CELL_TYP
[7:0] 
- 0xffff 
CELL_TYPE [3:0]  This code 
depends on battery data format. In the 
future, this code may be added. 
0x00: NiMH 
0x01: Li-ion 
0x10: Non-rechargeable battery 
(Reserved) 
1
st
 Battery 
[ _BIF ] 
18h 
*3 
OEM 
Information 
R(/W) 
DATA 
[15:8]  
*1 
All bits 
are 0 
Vender[7:0] - 
0xffff 
Vender [7:0] This code depends on 
battery data format. 
And the following name should be 
described in the ASL with the same 
character code. 
In the future, these codes will be 
added. 
0: “MoliEnergy” 
1: “Panasonic”  
2:  (SANYO does not agree the vender 
      name display) 
3: “TBCL”  (Toshiba) 
4: “Sony” 
 
*1: 
The register type is word. 
*3: 
This register is not cleared if the system is in S4-S5 state. 
R(/W): 
This is the read only register, but the written data will be able to read back till PMU updates the data 
periodically, or PMU detects the status change. 
 
3-36 
FIC M295 / M296 Service Manual