Cissell CAB438C User Manual

Page of 32
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
AJ0975
8
Operating Controls and Indicators
Table 1 (Continued)
Controls or 
Indicators
Function
Position or Indication
1. Red stop button
Stops electrical service to blowers, timers, and heat exchanger.
Press to actuate.
2. Cycle timer control 
knob
Determines pressing cyle time.
Rotate knob to desired 
setting.
3. Steam timer control 
knob
Determines the length of sleeve steaming time. Normally set at 
 
5 seconds.
Rotate knob to desired 
setting.
4. Water gun needle 
valve
Turns water on and off to water spray gun.
Turn clockwise to turn 
water off. Turn 
counterclockwise to turn 
water on.
5. Reset button
Energizes the air power control circuit. Press must be reset if press gauge 
(item 6) registers 0 psi.
With buck in the out 
position, press reset 
button.
6. Gauge, reset system
Indicates that air power is on or off to press.
When gauge shows line 
pressure, air is reset to 
press. When gauge shows 
zero pressure, air must be 
reset for press to operate.
7. Right gray buck in 
button
When pressed simultaneously with the left gray buck in button 
(item 13), moves buck from dressing position to pressing position inside 
cabinet.
Press simultaneously 
with left gray buck in 
button (item 13) to 
actuate.
8. Black vacuum 
release button
Turns vacuum off to buck.
Press to actuate.
9. Emergency Stop 
button
Exhausts entire air system except for air to collar clamp air cylinder. 
Stops buck travel and opens press heads or keeps press heads from 
closing. Press will not operate until air circuit is reset. (Applies to 
machines produced after 1997.)
Press to actuate. Turn in 
direction of arrow on 
button to reset. Button 
will pop up after 
approximately 1/8 turn.
10. Collar clamp foot 
pedal
Opens clamping arm on collar clamp (item 16).
Depress foot pedal to 
open collar clamp. 
Release foot pedal to 
close collar clamp.
11. Sleeve extender/
vacuum foot pedal
Moves the sleeve extenders out and turns vacuum on to buck.
Depress foot pedal to 
actuate.
12. Sleeve extender 
release button
Retracts sleeve extenders, which brings them in toward the buck. Should 
be actuated before dressing shirt on buck.
Press to actuate.
13. Left gray buck in 
button
When pressed simultaneously with the right gray buck in button 
(item 7), moves buck from dressing position to pressing position inside 
cabinet.
Press simultaneously 
with right gray buck in 
button (item 7) to actuate.
14. Red head release 
button
Opens the press heads. Buck will automatically return to the dressing 
position when heads open.
Press to actuate.