Post-Operating Services
Perform the following services after the final operation 
of the day or anytime press will be idle for an extended 
period of time:
1. Turn off steam to buck sleeve openings by 
pressing the steam Timer Selector switch to the 
off position. 
2. Mist air bags with water and send unloaded buck 
into pressing cabinet (this will prolong the life of 
the air bag and eliminate formation of wrinkles in 
air bags). Repeat 4 times.
3. Press one safety bar to relieve air pressure and 
stop blower.
4. Open customer-furnished electrical disconnect 
switch or trip the circuit breaker.
5. Close steam shut-off valve.
6. Close shut-off valve at air inlet.
7. Clean buck padding with a damp cloth. Check 
condition of buck padding and air bags. Replace 
padding if:
Cover is scorched or torn.
Bags have holes.
Flannel is hard or brittle (not springy).
8. Clean press heads if required.
Cleaning Press Heads
Press heads require cleaning if:
Discoloration transfers from head to shirts.
Shirts stick to heads as the heads open.
Once precautions listed in these WARNINGS have 
been met, follow directions provided with surface 
cleaner to clean press heads.
To avoid possible serious injury, heads 
should be cleaned ONLY by properly 
trained personnel.
W376
WARNING
To avoid possible serious injury, ALWAYS 
shut off services to press BEFORE 
removing guards and covers to clean 
press heads.
• Shut off AND lock out ALL electrical 
power to press.
• Shut off AND lock out ALL air pressure 
to press using the relieving shut-off 
valve at air supply inlet.
• Reduce steam pressure to 0 AND lock 
out steam supply to press.
• Let heated surfaces cool.
W377
WARNING
If using a surface cleaner which requires 
heat to the press, use an industry 
approved heat protective mitt or other 
heat protective device as press heads are 
cooling down.
W378
WARNING