Ciprico Media Vault 4400 User Manual

Page of 129
MV 4440_Ciprico Inc.   
                                                                                                                   
4-7
MediaVault 4440 User Manual
Installation    
Daisy Chaining
MV 4440 units include a hub feature, which allows up to 4 vPODs to be 
daisy chained. The built-in hub LEDs are located between the two Fibre 
Channel ports, as shown in Figure 4-7.
FIGURE 4-7.
 Built-In Hub, Showing the LEDs Located Between the Fibre Channels.
Hub Description
Table 4-3 describes the function of each hub LED. See Figure 4-7 for the 
location of the Fibre Channel ports and LEDs.
TABLE 4-3. 
Built-In Hub LEDs.
FC Port 1, FC Port 2
Fibre Channel 4 Gb SFP connection
LINK LED
FC communication established between the MediaVault controller 
and the built-in hub.
SYNC LED
A FC connection is established between the built-in hub portion of 
the MV 4440 and the device to which this port is connected.
ACTIVE LED
Data being transmitted to or from the Fibre Channel connector.