Ciprico Media Vault 4400 User Manual

Page of 129
Operations
MediaVault 4440 User Manual
5-8 
                                                                                                                    
MV 4440_Ciprico Inc.
Unit Power-Up Sequence
Always power-up the MV 4440 before powering-up the host computer. 
This allows the disk drive modules, and the data access/data transmission 
functions of the MV 4440, to be fully operational before the host computer 
is booted-up and “sees” the MV 4440 activities.
LED Power-On Sequence
The front panel LEDs of the MV 4440 power-up in the following sequence 
(per vPOD). Depending on the size of the drive, some LEDs might blink on 
momentarily, go off, then illuminate fully after a minute or so.
.
TABLE 5-4. 
LED Power-On Sequence, Each vPOD
1.
All LEDs are briefly illuminated when the MV 4440 is powered-up.
2.
POWER LED.
3.
4 Gb LED or 2 Gb LED (illuminates after host computer is powered-up. If MV 4440 is set to Auto or 1 Gb 
at power-up, the LED does not illuminate).
4.
ACTIVE LED (blinks momentarily before illuminating fully).
5.
RAID 6 LED (illuminated only if the vPOD is in RAID 6 when it is powered-up).
6.
SERVICE LED (is illuminated only when 1 or more drives in a vPOD is malfunctioning)
7.