Chauvet 160-LED User Manual

Page of 24
Technical Information 
 
 
Q-Spot™ 160-LED User Manual Rev. 01b 
 
-17- 
Troubleshooting Guide 
 
 
 
Symptom 
Cause(s) 
Action(s) 
Low LED output 
•  Dirty optics 
•  Clean optic path 
•  Dimmer active 
•  Check dimmer setting from control panel 
•  Faulty LED 
•  Replace LED board 
•  Faulty LED driver board 
•  Replace LED driver board 
•  Faulty main board 
•  Replace main board 
No LED output 
•  Dimmer set to 0% 
•  Check dimmer setting from control panel 
•  Faulty LED 
•  Replace LED board 
•  Faulty LED driver board 
•  Replace LED driver board 
•  Faulty main board 
•  Replace main board 
Jumpy or no head 
movement 
•  Faulty sensor 
•  Replace sensor 
•  Faulty wiring 
•  Check and repair wiring 
•  Faulty synch belt 
•  Replace synch belt 
•  Faulty X/Y control board 
•  Replace X/Y control board 
•  Faulty main board 
•  Replace main board 
•  Faulty stepper motor 
•  Replace stepper motor 
Fixture does not power up 
•  No power 
•  Check for power on power outlet 
•  Loose or damaged power cord 
•  Check power cord 
•  Blown fuse 
•  Replace fuse 
•  Faulty internal power supply 
•  Replace internal power supply 
Circuit breaker/fuse keeps 
tripping/blowing 
•  Excessive circuit load 
•  Check total load placed on the electrical circuit 
•  Short circuit along the power wires 
•  Check for a short in the electrical wiring 
Fixture does not respond 
to DMX 
•  Wrong DMX addressing 
•  Check Control Panel and unit addressing  
•  Damaged DMX cables 
•  Check DMX cables 
•  Wrong polarity on the controller 
•  Check polarity switch settings on the controller 
•  Loose DMX cables 
•  Check cable connections 
•  Faulty display board 
•  Replace display board 
•  Faulty main board 
•  Replace main board 
DMX signal problems 
•  Non DMX cables 
•  Use only DMX compatible cables 
•  Bouncing signals 
•  Install terminator as suggested 
•  Long cable / low level signal 
•  Install an optically coupled DMX splitter right 
after the fixture with the strong signal  
•  Too many fixtures 
•  Install an optically coupled DMX splitter after 
unit #32 or before 
•  Interference from AC wires 
•  Keep DMX cables separated from power 
cables or fluorescent/black lights 
 
 
 
 
 
 
If you still experience technical problems after trying the above solutions, contact 