Charnwood Grosvenor User Manual

Page of 9
Please go through this section with the installation
engineer so that you fully understand all the basic
operating and maintenance procedures for your stove.
The engineer will be happy to answer your questions and
give you any help you may need.
General Notes
This stove is not for use with any solid fuels. It is only
suitable for Natural (mains) Gas or LPG (Liquified
Petroleum Gas) when the correct burner is fitted.
Please remember that when the stove is alight it is very
hot.
EXCEPT FOR THE CONTROLS NEVER TOUCH
THE STOVE WITH YOUR BARE HANDS WHILST
IT IS HOT.
The stove must not be touched when it is in operation.
However, if you do need to do so after it has been turned
off and before it has completely cooled down (usually after
about one hour) please make sure that you wear stout oven
gloves.
Flue Spillage Safety Monitoring Device
A Safety Cut-Off System.
All stoves are fitted with an Oxygen Depletion Sensitive
Pilot so that should the flue and/or chimney become
blocked at any time, the stove will automatically cut off.
Normally the pilot can be re-ignited after waiting about
five minutes for the sensor to cool down, but in the event
of the system tripping, have the flue and chimney checked
by your installation engineer.
Lighting and controlling the stove.
Remember that the stove is designed to be operated with
the door and spinwheel securely closed.
1. Near the stove will be the gas isolation tap. Turn this to
the on position.
2. Between the front and rear legs on the right hand side of
the stove you will find the burner control knob, as shown
in Fig. 1.
a. Switching On/ Ignition.
Depress the control knob and turn counter clockwise. Gas
will flow to the pilot burner, the piezo igniter will give off
a high voltage spark & the pilot burner will light. (More
than one attempt may have to be made on first lighting the
fire.) Keep the control knob depressed for approximately
10 seconds to heat up the thermocouple, Turn the control
knob fully counter clockwise to release gas to the main
burner.
b. Control of Gas Flow.
Turning the control knob clockwise reduces the gas rate
from the maximum to the pre-set minimum setting.
Turning between maximum & minimum does not actuate
the piezo igniter. The control valve can only be set on pilot
by depressing the knob & turning it to the pre selected
pilot position.
c. Switching Off When in Pilot Position.
Press control knob and turn clockwise to off.
IMPORTANT
Interruption of Gas Supply.
Charnwood Grosvenor
Operating Instructions
Fig. 1. Gas Controls
Control Knob
Page 3
SV 2/00