CarAlarms P90-NG1 User Manual

Page of 48
Excalibur
®
 P90 Zero Clearance Direct Vent Gas Fireplace
27
9) 
Install the plastic bushing over the 
outside of the hole.
10)  Attach the ground wire to the DC spark 
mounting bracket.
11)  Attach the DC sparker generator wires to 
the DC sparker.
8) 
Insert both the ground wire and the DC 
sparker generator wire through the hole 
of the DC spark heat shield.
7) 
Attach the Piezo ignition wire to the DC 
Sparker.
Piezo 
Ignitor
13)  Attach the heat shield to the DC sparker, 
then mount this onto the stove. 
 
Note: We recommend attaching the 
DC sparker box to the bottom rear of 
the stove (or place this in a convenient 
location, away from the heat source).
14)  Tie up the loose wire with the wire clip.
Installation of the DC Sparker 
for the P90 Units Only:
1) 
Locate the Piezo Ignitor situated at the 
side of valve.
2) 
Remove the Piezo Ignitor by unscrewing 
the nut at the back of the mounting 
bracket.
3) 
Disconnect the ignitor wire from the 
Piezo Ignitor and connect it to the DC 
Sparker.
Piezo 
Ignitor
Ignitor 
Wire
Piezo 
Ignitor
Ignitor 
Wire
DC 
Sparker
4) 
Install the 3/4" nylon plug to cover up the 
hole on the mounting bracket.
12)  Install the supplied battery into the DC 
Sparker Box by opening the battery 
compartment.
 NOTE: The battery in the DC Sparker 
Box will need to be replaced annually.
Battery
Compartment 
INSTALLATION