 P90 Zero Clearance Direct Vent Gas Fireplace
39
5)  Connect fan ground cable to ground lug. 
Refer to wiring diagram.
6)   Slide the  thermodisc/cover assembly  into 
the bracket clip on the underside of the 
fi rebox. Check that no wire will touch the 
hot surfaces. Diagram 2.
Diagram 1
Diagram 2
Secure left side with 2 screws and right side 
with one screw.
8)  Secure the fan wires and power cord by 
attaching one of the adhesive backed wire 
holder clips (Part #910-199) onto the stove 
base. Use the second clip to bundle up the 
wires approximately 4" from the control box. 
Ensure that there is no interference with the 
wires when the louver is closed and that 
no wire will touch the hot metal surfaces or 
sharp edges.
9)  Plug the fan power cord into the rear end of 
the receptacle box to provide the maximum 
clearance from the louvers.
7)  Attach the two control boxes to the bottom 
unit base and tighten the 2 screws on the 
left side and 1 screw on the right side.
MAINTENANCE
To Remove the Fan
1)  Shut the power off.
2)  Reverse the above instructions.
Note:  The bearings are lubricated for life. Do 
not lubricate them. Make sure you vacuum 
the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within 
your home. Ensure you maintain these fan 
motors on a regular basis by vacuuming 
out the fan blades and housing using a soft 
brush nozzle.
FAN MAINTENANCE
Unit must be grounded at all times. Do 
not cut the ground terminal off under any 
circumstances.
To Install the Fan
1)  Shut the power off.
2)  Open the bottom louver door. Loosen the 2 
screws holding the Burner ON/OFF switch 
and bracket to the bottom louver and lift the 
assembly out.
3)  Remove the bottom louver door. 
4)  Slide the fan in towards the rear of the unit 
and slip it over the two mounting studs. Take 
care not to damage the insulation on the fan 
base. Ensure that the fan blades do not 
rub against the valve tubing. 
Diagram 
1.