Cabletron Systems 6A000/ZX-250 User Manual

Page of 268
SmartCell 6A000/ZX-250 Reference Manual   2-157
Console Commands
  
PVCByID
Use PVCByID (permanent virtual circuit by identification number) to manage cross-connect based PVCs on a 
cross-connect ID or sub ID.
Operators
activate, deactivate, delete
Parameters
Descriptions
SERVER
SVC
X
X
Input Parameter
Description
Value/Field Size
Default
[CrossConnId]
Identifies the PVC on the switch. Chronological 
sequential index marker of the circuits. 
0, 1, 2, 3, 4...
/n/a
0
[CrossConnSubId]
ID of the leaf in PMP connection.
0, 1, 2, 3, 4.../
n/a
0
Operator
Parameters/Permissions
Description
activate 
pvcbyid
[CrossConnId] <crossconnid>
[CrossConnSubId] 
<crossconnsubid>
Administrator
Activates a PVC by its unique identifier. Can be used instead 
of 
activate pvc
 and requires fewer input parameters if the 
PVC had been created using 
create pvc
. If the 
CrossConnSubId is “0”, then all the PVCs with same 
CrossConnId are deactivated.
deactivate 
pvcbyid
[CrossConnId] <crossconnid>
[CrossConnSubId] 
<crossconnsubid>
Administrator
Deactivates a PVC by its unique identifier. Can be used 
instead of 
deactivate pvc
 and requires fewer input 
parameters if the PVC had been created using 
create pvc
. If 
the CrossConnSubId is “0”, then all the PVCs with same 
CrossConnId are deactivated.