Cabletron Systems 6A000/ZX-250 User Manual

Page of 268
2-180   SmartCell 6A000/ZX-250 Reference Manual
  Console Commands
Descriptions
Examples
The following examples show a summarized and detailed listing of an SVC.
Summarized Report (</s>)
switch_prompt # show svc /s
PortNumber(ALL)                           :
CrossConnectId(ALL)                       :
Conn  Conn   Traffic Conn       Low                High           Admin
Id    SubId  Type    Type  Port    VPI/VCI     Port    VPI/VCI    Status
============================================================================
 4654    61  UBR     PTP   B4(CPU)   0/52      B4(CPU)   0/53     UP
 4655    63  UBR     PTP   B4(CPU)   0/54      B4(CPU)   0/55     UP
 4656    65  UBR     PMP   B4(CPU)   0/56      B4(CPU)   0/57     UP
switch_prompt #
[Number of Cells Received 
in the Bkwd Direction] 
(<
/d
>)
Number of cells received in the backward direction of this 
cross-connect.
0, 1, 2, 3, 4.../
n/a
[Number of Cells Dropped 
in the Bkwd Direction] 
(<
/d
>)
Number of cells dropped in the backward direction of this 
cross-connect.
0, 1, 2, 3, 4.../
n/a
[Number of EPD Packets 
Droppedin the Bkwd 
Direction] (<
/d
>)
Number of EPD packets dropped in the forward direction 
of this cross-connect.
0, 1, 2, 3, 4.../
n/a
Operator
Parameters/Permissions
Description
show svc (/s | 
/d)
[PortNumber] <portnumber>
[CrossConId <crossconnectid>
All
Displays SVCs configured for all ports or a specified port. 
The cross-connect ID is a unique number generated for every 
SVC. PMP SVCs have only one cross-connect ID, though 
they might have several legs. All cell statistics are updated 
every 40 seconds, which is the maximum time for holding 
these counters without overflowing them.
Output Parameter
Description
Value/Field Size