Page of 268
2-184   SmartCell 6A000/ZX-250 Reference Manual
  Console Commands
SwitchConfig
Use SwitchConfig (switch configuration) to manage switch-related parameters, like switchname and IP address.
Operators
modify, show
Parameters
SERVER
SVC
X
X
Input Parameter
Description
Value/Field Size
Default
[SwitchName]
Name of the switch.
1-19 characters
switch_1
[IPAddress]
IP address of Ethernet port on the switch. dot decimal/
7-15 characters
1.1.1.200
[IPNetMask]
IP netmask of the client. Defaults to the 
appropriate netmask, based on IP address 
class. Calculated from the first two high 
bits of the IP address. Must be specified 
only if IP subnets are being used.
dot decimal/
7-15 characters
255.0.0.0, 
255.255.0.0 or 
255.255.255.0
Output Parameter 
Description
Value/Field Size
[CPU Model]
Model of the i960 CPU.
Up to 7 characters
[CPUSpeed]
Speed of the CPU.
25 (CA) - 33 (CF) MHz
[CPU Board ID]
Hardware version level of the CPU 
board.
1 character
[Secondary Flash Type]
Type of secondary flash.
ASYNCHRONOUS, SYNCHRONOUS
[CPU DRAM]
CPU DRAM memory size.
megabytes/Up to 4 characters