Cabletron Systems EMM-E6 User Manual

Page of 64
Connecting to the Network
EMM-E6 Installation Guide
3-17
3.5.4
Connecting an AUI Segment to an EPIM-X or 
EPIM-A
Attach an external transceiver to the network segment intended for AUI 
port connection. For additional information, refer to the applicable 
transceiver manual.
Attach an AUI cable, no longer than 50 meters in length, to the external 
transceiver.
1. Align the DB15 connector of the AUI cable with the AUI port of the 
2. Firmly press the AUI connector over the AUI port. If there is a slide 
latch present for the AUI connector, slide it over the locking posts on 
the DB15 port. 
Figure 3-9
AUI Connector Insertion
NOTE
Ensure that the external transceiver to which the EPIM-A 
connects does not have the signal quality error (SQE or 
“heartbeat”) test function enabled. The EPIM does not operate 
if the transceiver has the SQE test function enabled. Refer to 
the applicable transceiver manual for additional information.
1926n12
ICH1Book  Page 17  Tuesday, August 6, 1996  3:06 PM