Cabletron Systems EMM-E6 User Manual

Page of 64
Appendix A: Specifications
A-2
EMM-E6 Installation Guide
A.3
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
5
°
C to 40
°
C (41
°
F to 104
°
F)
Storage Temperature:
-30
°
C to 90
°
C (-22
°
F to 194
°
F)
Operating Humidity:
5% to 95% (non-condensing)
A.4
CERTIFICATION
Safety:
UL 1950, CSA C22.2 No. 950, EN 60950, and 
IEC 950
Emission:
FCC Part 15 Class A, VCCI Class I, and 
EN 55022 Class A
Immunity:
EN 50082-1
This unit has been tested by Bellcore and found to comply with the 
following Bellcore standards:
TR-NWT-000063
Network Equipment Building System (NEBS) 
Generic Equipment Requirements
GR-1098-CORE
EMC and Electrical Safety Generic Criteria for 
Network Telecommunications Equipment
A.5
COM PORT PINOUT
Type: Standard RJ45 port
Pin
Function
Connection Attitude
1
Transmit Data (XMT)
From COM 2 port
2
Data Carrier Detect (DCD)
From COM 2 port
3
Data Set Ready (DSR)
To COM 2 port
4
Receive Data (RCV)
To COM 2 port
5
Signal Ground (GND)
NA
6
Data Terminal Ready (DTR)
From COM 2 port
7
Request to Send (RTS)
To COM 2 port
8
Clear to Send (CTS)
NA
ICH1Book  Page 2  Tuesday, August 6, 1996  3:06 PM