4.2.3 GPIO 
The GPIO submenu enables you to configure all DI sensor and DO settings:
 
 
External DI sensors can be attached via the GPIO port at the rear of the camera. The 
external sensor can be normally open, or normally closed. A normally open sensor is 
like an open switch that closes when triggered. A normally closed sensor is like a 
closed switch that opens when triggered. This must be set correctly for an external 
sensor to function properly. You can connect up to two DI sensors to the camera. 
An external DO alarm can also be attached to the camera via the GPIO port at the rear 
of the camera. 
Under DI Configuration, select Normal Open or Normal Close for each DI1 and DI2. 
Click the Submit  button to confirm all settings. 
Under DO Configuration, select Normal Open or Normal Close for the DO alarm.  
Click the Submit button to confirm all settings.