Atlas Copco Stationary Air Compressors User Manual

Page of 70
Instruction book 
2920 1521 00 
26 
 
A1 Dryer 
(optional) 
F1/11 Fuses 
K11 
Auxiliary contactor, dryer 
K21/24 Contactors 
M1/4 Motors 
M5 
Fan motor, air cooler 
M6 
Fan motor, bodywork 
PT20 
Pressure sensor, air outlet 
Q21/24 Circuit 
breakers 
S3 
Emergency stop button 
TSHH20 
Temperature switch, air outlet protection 
TT11 
Temperature sensor, compressor element 1 (lowest element) 
TT12 
Temperature sensor, compressor element 2 
TT13 
Temperature sensor, compressor element 3 
TT14 
Temperature sensor, compressor element 4 (highest element) 
TT90 
Temperature sensor, dewpoint temperature 
T1/2 Transformers 
1X0 
Terminal strip, mains supply 
1X2 
Terminal strip, dryer 
1X3/6 Terminal 
strips 
 
Fig. 2.8 Service diagram for SF Multi  
 
 
 
Text on Fig. 2.8 
 
(1) Customer’s 
installation 
(2) Door 
(3) 
Higher voltage: Y 
Lower voltage: D 
(4) Dryer 
(5) Optional 
(6) 
Supply of dryer 
(7) 
All other voltages 
(8) 
Marking of connectors 2X5 to 2X12 
(9) 
Pressure transducer: pin configuration  
(10) 
Temperature sensor, element 1 
(11) 
Temperature sensor, element 2 
(12) 
Temperature sensor, element 3 
(13) 
Temperature sensor, element 4 
(14) 
Temperature sensor, LAT dryer 
(15) 
Pressure transducer, delivery air 
(16) 
Temperature switch, delivery air 
(17) FF 
only 
(18) Emergency 
stop 
(19) 
Remote start/ pr. Stop 
(20) 
Overload motor M1 
(21) 
Overload motor M2 
(22) 
Overload motor M3 
(23) 
Overload motor M4 
(24)  
Fault EWD 
(25) 
High temperature outlet 
(26)  
Remote pressure set point 
Selection: Open = set 1   Closed = set 2 
(27) 
Remote emergency stop 
(28) Auxiliary 
contacts