7 PRINCIPAL DATA 
 
7.1 Electric cable size for SF1-8 
 
Frequency Voltage 
SF1 
single-
phase 
SF2 
single-
phase 
SF2  
3-phase 
SF4  
3-phase 
SF6  
3-phase 
SF8  
3-phase 
 
 
 
 
 
 
 
 
IEC 
 
 
 
 
 
 
 
50 Hz 
230 V 
2.5 mm² 
2.5 mm² 
2.5 mm² 
2.5 mm² 
2x 2.5 
mm² 
2x 2.5 
mm² 
50 Hz 
400 V 
 
 
2.5 mm² 
2.5 mm² 
2x 2.5 
mm² 
2x 2.5 
mm² 
60 Hz 
380 V 
 
 
2.5 mm² 
2.5 mm² 
2x 2.5 
mm² 
2x 2.5 
mm² 
50 Hz 
500 V 
 
 
2.5 mm² 
2.5 mm² 
2x 2.5 
mm² 
2x 2.5 
mm² 
 
 
 
 
 
 
 
 
CSA/UL 
 
 
 
 
 
 
 
60 Hz 
200/230 V 
AWG 12 
AWG 12 
AWG 12 
AWG 10 
2x AWG 
12 
2x AWG 
10 
60 Hz 
440/460 V 
 
 
AWG 12 
AWG 12 
2x AWG 
12 
2x AWG 
12 
 
 
7.2 Electric cable size for SF 6-15 Multi 
 
Frequency Voltage 
SF6 
 
3-phase 
SF8  
3-phase 
SF11  
3-phase 
SF15  
3-phase 
 
 
 
 
 
 
IEC 
 
 
 
 
 
50 Hz 
230 V 
6 mm² 
10 mm² 
16 mm² 
25 mm² 
50 Hz 
400 V 
4 mm² 
6 mm² 
10 mm² 
10 mm² 
60 Hz 
380 V 
4 mm² 
6 mm² 
10 mm² 
10 mm² 
50 Hz 
500 V 
2.5 mm² 
4 mm² 
6 mm² 
10 mm² 
 
 
 
 
 
 
CSA/UL 
 
 
 
 
 
60 Hz 
200/230 V 
AWG 8 
AWG 6 
AWG 4 
AWG 3 
60 Hz 
440/460 V 
AWG 10 
AWG 10 
AWG 8 
AWG 6 
60 Hz 
575 V 
AWG 12 
AWG 10 
AWG 8 
AWG 6