8.9 Modifying protection settings 
 
Function 
 
1.  To modify protection settings: warning ("Warning"), e.g. Dryer LAT (Low Ambient Temperature) on 
Full-Feature machines 
2.  To check some compressor conditions, e.g. the status of the motor overload contacts per 
compressor module.  The list of parameters is shown in Fig. 8.1. 
 
Note 
Some parameters cannot be modified. 
 
Procedure 
 
1.  Starting from the Main screen (see section 8.1.2): 
press the key "Menu" (F1) 
- press 
the 
↓ key until the option "Modify parameters" is followed by a horizontal arrow 
press the tabulator key (5) to activate the menu 
2. Use 
the 
↓ key to scroll until the option "Protections" is followed by a horizontal arrow. 
3.  Press the tabulator key (5): the first item ("Compressor outlet") and its value will appear. 
4. Use 
the 
↓ key to scroll until the parameter to be modified or checked is followed by a horizontal 
arrow. 
5.  press the tabulator key (5) to select the parameter 
 
 
8.9.1 Checking protections for compressor modules 
 
1.  Consult the section above to select the parameter Element 1: 
 
Element 1 
 
70 °C 
 
 
 
Warning Maximum 
75 
°C 
Back  
 
F1 F2 F3 
 
Fig. 8.13 Modify parameters menu 
 
 
2.  The screen shows that the current temperature is 70 °C and that the shut-down setting is 75 °C.