Areca ARC-1110 User Manual

Page of 180
139
WEB BROWSER-BASED CONFIGURATION
Allow Read Ahead (Default: Enabled)—When Enabled, the drive’
s  read  ahead  cache  algorithm  is  used,  providing  maximum 
performance under most circumstances.
• 
Stagger Power on 
In  a  PC  system  with  only  one  or  two  drives,  the  power  can 
supply enough power to spin up both drives simultaneously. But 
in systems with more than two drives, the startup current from 
spinning up the drives all at once can overload the power supply, 
causing  damage  to  the  power  supply,  disk  drives  and  other 
system  components.  This  damage  can  be  avoided  by  allowing 
the host to stagger the spin-up of the drives. New SATA drives 
have support staggered spin-up capabilities to boost reliability. 
Staggered spin-up is a very useful feature for managing multiple 
disk drives in a storage subsystem. It gives the host the ability 
to  spin  up  the  disk  drives  sequentially  or  in  groups,  allowing 
the drives to come ready at the optimum time without straining 
the system power supply. Staggering drive spin-up in a multiple 
drive environment also avoids the extra cost of a power supply 
designed to meet short-term startup power demand as well as 
steady state conditions. 
Areca has supported the fixed value staggered power up function 
in  its  previous  version  firmware.  But  from  firmware  version 
1.39 and later, SATA RAID controller has included the option for 
customer to select the disk drives sequentially stagger power up 
value.  The values can be selected from 0.4ms to 6ms per step 
which powers up one drive.