Areca ARC-1110 User Manual

Page of 180
INTRODUCTION
23
1.5 High Reliability
1.5.1 Hard Drive Failure Prediction
In an effort to help users avoid data loss, disk manufacturers are 
now incorporating logic into their drives that acts as an "early 
warning system" for pending drive problems. This system is called 
S.M.A.R.T. The disk integrated controller works with multiple 
sensors to monitor various aspects of the drive's performance, 
determines from this information if the drive is behaving normally 
or not, and makes available status information to RAID controller 
firmware that probes the drive and look at it.
The SMART can often predict a problem before failure occurs. 
The controllers will recognize a SMART error code and notify the 
administer of an impending hard drive failure.
1.5.2 Auto Reassign Sector
Under normal operation, even initially defect-free drive media can 
develop defects. This is a common phenomenon. The bit density 
and rotational speed of disks is increasing every year, and so is 
the potential of problems. Usually a drive can internally remap 
bad sectors without external help using cyclic redundancy check 
(CRC) checksums stored at the end of each sector.  
SATA drives perform automatic defect re-assignment for both 
read and write errors. Writes are always completed - if a location 
to be written is found to be defective, the drive will automatically 
relocate that write command to a new location and map out the 
defective location. If there is a recoverable read error, the cor-
rect data will be transferred to the host and that location will be 
tested by the drive to be certain the location is not defective. If 
it is found to have a defect, data will be automatically relocated, 
and the defective location is mapped out to prevent future write 
attempts. 
In the event of an unrecoverable read error, the error will be 
reported to the host and the location flagged as potentially defec-
tive. A subsequent write to that location will initiate a sector test 
and relocation should that location have a defect. Auto Reassign 
Sector does not affect disk subsystem performance because it