APOLLO 120/150 III 
9-178
E-1-3: I
NTERNATIONAL 
S
TANDARD
 
² Safety standards 
Designed to meet the following standards 
UR 
TUV 
FCC B 
CE 
 
E-1-4: M
ECHANICAL 
S
PECIFICATION
 
Output 
rating 
+3.3V 
+5V 
+12V 
-5V 
-12V  +5V
SB
 
 
min. 
max. 
min. 
max 
peak 
min. 
max 
peak 
min 
max min 
max min 
max 
Ripple & 
noise 
100mV 
100mV 
150mV 
200mV  200mV  100mV 
Regulation  5% 
5% 
5% 
10% 
10% 
5% 
Output 
rating 
0.5A 
7A  1A  12A 14A 0.5A 
5A 8A  0A 0.2A 
0A 1A  0
A
 2A 
 
83W 
MAX
 
 
 
   
   
   
 
² Dimension (unit: mm) 
180 x 100 x 40.5 (L x W x H)