Apollo SWING GATE OPERATOR 1500 User Manual

Page of 17
14 
TROUBLESHOOTING OPERATOR & ACCESSORIES 
SYMPTOM 
Some troubleshooting will require a hand held multimeter. An inexpensive digital multimeter may be 
purchased at Radio Shack or a local electric supply company. Refer to the owners manual for 
instructions.  
Gate opens OK but after closing, opens back up. 
1. Excessive closing pressure on gate. Re-adjust the close limit switch on the actuator. 
 
2. Automatic reverse sensitivity is set too sensitive. Re-adjust - CAUTION: Automatic reverse sensitivity  
 
should be set sensitive enough to avoid injury. 
  
3. Gate is mechanically binding. Disconnect actuator from gate and eliminate binding. 
 
4. Battery voltage is too low. Battery voltage should be 12 to 14 volts under load. Check solar panel output or 
 
battery charger output or re-evaluate usage. 
 
5. Replace circuit board.  
SYMPTOM 
Gate moves only a few feet, then stops or reverses. 
1. Battery voltage is too low. Battery voltage should be 12 to 14 volts under load. Check solar panel output or 
 
battery charger output or reevaluate usage. 
 
2. Gate is mechanically binding. Disconnect actuator from gate and eliminate binding. 
 
3. Actuator extension tube is bent. Inspect for damage and replace extension tube if required. 
 
4. Current sensitivity is adjusted too sensitive. Re-adjust current sensitivity. 
 
5. Replace circuit board. 
SYMPTOM 
Gate surges too much. Does not run smooth. 
1. Pivot arm is not ridged. Re-weld and/or brace pivot arm. 
 
2. Bolts are loose. Snug all bolts. Pivot arm bolt should be snug but not tight. 
 
3. Gate is too limber. Reinforce gate.