95
 
5.  DISPLAY SWITCH IS SET INCORRECTLY 
Display switch on the motherboard can be set to either monochrome or color. This indicates 
the switch is set to a different setting than indicated in Setup. Determine which setting is 
correct, and then either turn off the system and change the jumper, or enter Setup and 
change the VIDEO selection. 
6.  DISPLAY TYPE HAS CHANGED SINCE LAST BOOT 
Since last powering off the system, the display adapter has been changed. You must 
configure the system for the new display type. 
7. EISA 
Configuration Checksum Error 
PLEASE RUN EISA CONFIGURATION UTILITY 
The EISA non-volatile RAM checksum is incorrect or cannot correctly read the EISA slot. 
This can indicate either the EISA non-volatile memory has become corrupt or the slot has 
been configured incorrectly. Also be sure the card is installed firmly in the slot. 
8.  EISA Configuration Is Not Complete 
PLEASE RUN EISA CONFIGURATION UTILITY 
The slot configuration information stored in the EISA non-volatile memory is incomplete. 
Note: 
When either of these errors appears, the system will boot in ISA mode, 
which allows you to run the EISA Configuration Utility. 
9.  ERROR ENCOUNTERED INITIALIZING HARD DRIVE 
Hard drive cannot be initialized. Be sure the adapter is installed correctly and all cables are 
correctly and firmly attached. Also be sure the correct hard drive type is selected in Setup. 
10. ERROR INITIALIZING HARD DISK CONTROLLER 
Cannot initialize controller. Make sure the cord is correctly and firmly installed in the bus.   
Be sure the correct hard drive type is selected in Setup. Also check to see if any jumper 
needs to be set correctly on the hard drive. 
11.  FLOPPY DISK CNTRLR ERROR OR NO CNTRLR PRESENT 
Cannot find or initialize the floppy drive controller. Make sure the controller is installed 
correctly and firmly. If there are no floppy drives installed, be sure the Diskette Drive 
selection in Setup is set to NONE.