Apex Digital DESTINY 4100 K1106 User Manual

Page of 60
21
Zone 1
Zone 2
Input
Control Board Loop 1
Input
Control Board Loop 2
Option
Location
Default
New Value
Option
Location
Default
New Value
Zone Type
0647
255
Zone Type
0663
255
Option 1
0643
080
Option 1
0659
080
Option 2
0644
000
Option 2
0660
000
Supervision
1106
000
Supervision
1110
000
Word 1
Word 3
Word 1
Word 3
Word 2
Word 4
Word 2
Word 4
Zone 3
Zone 4
Input
Control Board Loop 3
Input
Control Board Loop 4
Option
Location
Default
New Value
Option
Location
Default
New Value
Zone Type
0679
255
Zone Type
0695
255
Option 1
0675
080
Option 1
0691
080
Option 2
0676
000
Option 2
0692
000
Supervision
1114
000
Supervision
1118
000
Word 1
Word 3
Word 1
Word 3
Word 2
Word 4
Word 2
Word 4
Zone 5
Zone 6
Input
Control Board Loop 5
Input
Control Board Loop 6
Option
Location
Default
New Value
Option
Location
Default
New Value
Zone Type
0711
255
Zone Type
0727
255
Option 1
0707
080
Option 1
0723
080
Option 2
0708
000
Option 2
0724
000
Supervision
1122
000
Supervision
1126
000
Word 1
Word 3
Word 1
Word 3
Word 2
Word 4
Word 2
Word 4
Zone 7
Zone 8
Input
Control Board Loop 7
Input
Control Board Loop 8
Option
Location
Default
New Value
Option
Location
Default
New Value
Zone Type
0743
255
Zone Type
0759
255
Option 1
0739
080
Option 1
0755
080
Option 2
0740
000
Option 2
0756
000
Supervision
1130
000
Supervision
1134
000
Word 1
Word 3
Word 1
Word 3
Word 2
Word 4
Word 2
Word 4
Zones 1 - 8: System Controller
At default, all 8 system inputs are disabled.  To enable a hardware input, enter a zone type in the zone type
location.
Example: To enable Zone 1 (Input 1) and assign it as an Exterior Instant, enter 0647,000
Generally, this is all of the programming necessary to activate a zone.  There are 4 spaces in each zone record to
note a zone description.  At the end of the zone programming section are detailed instructions for entering zone
descriptions and a complete listing of the system vocabulary.
Other options:
Each input is defaulted to use a single End-Of-Line Resistor(EOLR).  For certain installations, it may be necessary to
use full 2-resistor supervision or for ease of installation, no EOLR.  To adjust the supervision setting, enter the
appropriate value in the supervision location.
Options
 Value
2 end-of-line resistor supervision .................................................................................................... 064
No end of line resistor (Not permitted in a UL installation) ............................................................. 128
Default (1 end-of-line resistor) ....................................................................................................... 000