Ademco Contact ID Report Codes
APEX Description
Code Sent to Central Station
ADEMCO Description
Exterior instant .................................. E 131 Z ............................................Perimeter burglary
Exterior delay 1 .................................E 134 Z ............................................Entry/exit burglary
Exterior delay 2 .................................E 134 Z ............................................Entry/exit burglary
Interior instant ...................................E 132 Z ............................................Interior burglary
Interior delay 1 .................................. E 132 Z ............................................Interior burglary
Interior delay 2 .................................. E 132 Z ............................................Interior burglary
Fire .................................................... E 110 Z ............................................Fire alarm
Panic .................................................E 120 Z ............................................Panic alarm
Silent panic .......................................E 122 Z ............................................Silent
Emergency ........................................ E 100 Z ............................................Medical
Follower ............................................ E 132 Z ............................................Interior burglary
Auxiliary ...........................................E 150 Z ............................................24 hour nonburglary
Duress disarm ...................................E 121 0 ............................................Duress
Duress when not armed .................... E 121 0 ............................................Duress
Zone restore after activation .............. R 140 Z ............................................General Alarm
Transmitter low battery ...................... E 384 Z ............................................RF low battery
Transmitter battery restore .................R 384 Z ............................................RF low battery
Zone trouble .....................................E 370 Z ............................................Protection loop
Zone trouble restore .......................... R 370 Z ............................................Protection loop
High current trouble .......................... E 300 91 ..........................................System trouble
High current restore .......................... R 300 91 ..........................................System trouble
Phone line restore .............................R 350 28 ..........................................Communication
Open (disarm) ...................................E 401 U ...........................................Open by user
Open after activation ........................ E 450 U ...........................................Exception open
Close (arm) ........................................ R 401 U ...........................................Close by user
Force Arm .........................................R 450 U ...........................................Exception close
Control low battery ...........................E 302 29 ..........................................Low system battery
Control battery restore .......................R 302 29 ..........................................Low system battery
AC fail ...............................................E 301 29 ..........................................AC loss
AC restore .........................................R 301 29 ..........................................AC loss
User communicator test .................... E 601 Z ............................................Manual trigger test
Automatic communicator test ...........E 602 99 ..........................................Periodic test report
Cancel ...............................................E 406 Z ............................................Cancel
Zone bypass ...................................... E 570 Z ............................................Zone bypass
Zone unbypass .................................. R 570 Z ............................................Zone bypass
Day zone trouble .............................. E 135 Z ............................................Day alarm
Day zone trouble restore ...................R 135 Z ............................................Day alarm
Upload/download attempt .................E 412 99 ..........................................Success - download/access
Program mode entry .......................... E 627 99 ..........................................Program mode entry
Fail to open .......................................E 453 99 ..........................................Failed to open
Fail to close .......................................E 454 99 ..........................................Failed to close
Zone open .........................................E 371 Z ............................................Protection Loop
Zone restore ...................................... R 371 Z ............................................Protection Loop
Tamper .............................................. E 383 Z ............................................Zone tamper
Tamper Restore.................................. R 383 Z ............................................Zone tamper restore
Receiver Supervision Trouble ............ E 355 Z ............................................Loss of radio supervision
Receiver Supervision Trouble Restore R 355 Z ............................................Loss of radio supervision