Programming
55
 Metreau Entry Communicators 
Face Plate LED Commands
Metreau Entry Communicators support the following LED face plate SEND_COMMANDs on port 1. 
Face Plate LED Commands
SET LED-LEVEL
Adjusts the brightness of the LED. 
To turn the LED ON or OFF. 
Syntax:
SEND_COMMAND <DEV>,"'SET LED-LEVEL <state> 
<level>'"
Variable:
•    State = ON, OFF
•    Level = 0 – 100. Represents 0%(dimmest) to 100% brightest.
Example:
SEND_COMMAND MET1,'"SET LED-LEVEL ON 50'"
Sets the LED brightness level ON at 50%.
GET LED-LEVEL
Retrieves the brightness of the 
LED. To turn the LED ON or OFF. 
Syntax:
SEND_COMMAND <DEV>,"'GET LED-LEVEL'"
Example:
SEND_COMMAND MET1,"'GET LED-LEVEL'"
Returns:
LEDLEVEL = <state> <level>
SET LED-STATE
Sets the state of the front button 
LED.
Syntax:
SEND_COMMAND <DEV>,"'SET LED-STATE <State>’"
Variable:
•    State = IDLE, ACTIVE
Example:
SEND_COMMAND MET1,"'GET LED-STATE ACTIVE’"
Sets the LEDS in an active pulsing state.
GET LED-STATE
Retrieves the brightness of the 
LED. To turn the LED ON or OFF. 
Syntax:
SEND_COMMAND <DEV>,"'GET LED-STATE'"
Returns:
IDLE, ACTIVE
Example:
SEND_COMMAND MET1,"'GET LED-STATE’"
Returns:
’LEDSTATE = ACTIVE’