American Dynamics MegaPower CPU ADMPCPU User Manual

Page of 86
MEGAPOWER CPU 
8200-0421-03, REV. G 
ADMINISTRATOR’S GUIDE 
10 of 82
 
4.  Switch on the CPU. The LCD screen displays the 
AD Welcome Screen (Figure 10), followed by the 
CPU Status screen, two examples of which are 
shown in Figure 11. 
Figure 10. AD welcome screen 
 
Figure 11. CPU status screen 
   or    
 
Using an IP Address Assigned by the 
Network DHCP Server 
To set up the MegaPower CPU to obtain an IP 
address from a DHCP server, do the following: 
1.  Connect a keyboard to an RS-232 port on the 
MegaPower CPU. Ensure the baud rates match 
for the keyboard and CPU port in use. 
2.  Use the following instructions to provide the key 
sequences for each supported keyboard: 
AD2088:  
a.  Place the keyboard in Menu Mode by turning 
the keyswitch to MENU.  The Camera field 
LED on the keyboard should display P6
b.  Enter one of the following number sequences 
for your MegaPower CPU installation: 
○  Standalone MPCPU: Enter 100
○  Dual MPCPU: Enter 100 for the selected 
MegaPower CPU, or enter 101 for the 
Standby MP CPU. 
c. Press the ENTER key, which is located above 
the joystick. “ENTER” is stenciled on the front 
face of the key; the top of the key may be 
labeled either PRESET or SHOT. 
The Camera field LED on the keyboard will 
only display 7P if the selected CPU is 
accessed. 
ADCC1100:  
a.  Place the keyboard in Program Mode by 
clicking the tab in the middle of the lower part 
of the screen). 
Note: To display and enter Program Mode, you 
must insert a Smartcard that has administrator 
privileges. 
b. Press the Matrix Menus softkey. 
c.  Enter one of the following number sequences 
for your MegaPower CPU installation: 
○  Standalone MPCPU: Enter 100
○  Dual MPCPU: Enter 100 for the selected 
MegaPower CPU, or enter 101 for the 
Standby MP CPU. 
d. Press the Enter softkey. 
ADCC0200/0300
Notes: In RS–232 mode, the ADCC0200 
keyboard does not have matrix menu access 
capabilities as indicated by the Access Denied 
message if the following procedure is attempted. 
a.  Press and hold the Shift (
) button and then 
press the Menu (
) button. 
b.  Enter one of the following number sequences 
for your MegaPower CPU installation: 
○  Standalone MPCPU: Enter 100
○  Dual MPCPU: Enter 100 for the selected 
MegaPower CPU, or enter 101 for the 
Standby MP CPU. 
c. Press Enter ( ). 
Note: Whenever scrolling to a different line 
item on the LCD screen, you must press   
twice to select the new item. 
Note: To exit Program Mode, press and hold the 
Shift (
) button, and then press the Clear (
button. 
ADTTE:  
a.  Place the keyboard in Program Mode 
(indicated by –P being displayed at the far right 
of the LCD). 
b. Press the Menu key. The LCD screen displays 
P6 - M
c.  Enter one of the following number sequences 
for your MegaPower CPU installation: 
○  Standalone MPCPU: Enter 100