MEGAPOWER CPU 
8200-0421-03, REV. G 
ADMINISTRATOR’S GUIDE 
43 of 82
 
Figure 88. Definitions – Cameras screen 
 
The Definitions – Cameras screen can be split into 
an upper and lower screen. 
•  The upper screen shows existing camera 
definitions and allows you to add new definitions. 
All of the fields can be edited except the 
Dome/PTZ Connection and Dome/PTZ Address, 
which are read-only fields. The Dome/PTZ 
Connection field displays codes identifying the 
connection type: M for Manchester, S for 
SensorNet, and R for RS-232/ RS-485. This field 
is also highlighted in red if the connection is 
configured to go out the ADDL. The Dome/PTZ 
Address shows the address configured for the 
dome. 
The Calling Contacts and Salvo Contacts fields 
only display a range value until selected for edit. 
•  The lower screen only appears when either the 
Calling Contacts field or Salvo Callups field is 
selected, and provides a tab that allows you to do 
the following: 
−  Calling Contacts – View and edit alarm 
contacts associated to call a camera. See 
Adding and Deleting Calling Contacts to 
Cameras
 on page 44. 
−  Salvo Callups – View and edit Salvo call-ups 
associated with selected cameras. See 
Associating Salvo Callups to Cameras on 
page 45. 
Adding Camera Definitions 
You can create and edit camera definitions. 
1.  To add new camera definitions, click Add on the 
right side of the screen. The Add Cameras dialog 
box appears. 
Figure 89. Add Cameras dialog 
 
2.  Complete the following fields: 
•  Number of Cameras – Enter the number of 
cameras you want to define. The system will 
number these cameras consecutively starting 
with the next highest available number. 
Camera numbers identify the video input 
connection number on the switcher. 
Note: If multiple cameras are defined at the 
same time, they share the same video loss 
detection, site, output, pan/tilt, alarm number, 
and location. You can edit each camera’s 
definition after they have been created. 
•  Pseudo Number – Pseudo numbers are 
unique identifiers you can give cameras to help 
identify their location or purpose. For example, 
you could number the cameras on the first floor 
of a building starting with 1000, such as: 1001, 
1002, 1003, etc. You could use 2000 for 
second floor cameras, 3000 for third floor 
cameras and so on. 
The pseudo number is assigned starting with 
the first camera you specify and is incremented 
by 1 for each additional camera specified.