AMCC 9550SX-8LP User Manual

Page of 40
www.3ware.com
23
Chapter 2. Installing the 
Battery Backup Unit
The Battery Backup Unit (BBU) is an add-on that can be attached 
to a 3ware 9550SX RAID controller to supply power to the memory 
module from an attached battery pack in the event of a system 
power loss. This allows the controller to use write-caching for 
optimal performance and not be exposed to data loss in the event of 
a system power failure. When fully charged, the battery preserves 
the contents of the controller cache memory for a limited period of 
time (up to 72 hours). When power is restored, cached data is 
flushed to disks. 
Caution:
 
Both the 3ware RAID controller and the BBU 
are sensitive electronic equipment and can be damaged 
through electrostatic discharge. When installing the 
BBU on the controller, be sure you are grounded. Use a 
grounding strap, or work on an ESD-protective mat. 
„
Do not remove the 3ware controller or BBU from their 
protective bags until you are properly grounded. 
„
Handle the 3ware RAID controller by its edges or by 
the metal bracket at its end.
„
Do not touch any pin, contact, lead, or component on 
the 3ware RAID controller. 
Important:
 The battery is a heat-sensitive component. 
The cooler the battery, the longer the battery lasts. If 
possible, place the controller with the BBU in a slot with 
good airflow, away from components that generate the 
most heat in the system, such as video cards. 
Note:
 The battery will drain if it is plugged into the BBU 
and there is no power to the unit. Wait to  plug the 
battery into the BBU until the system is ready for use.