5.1
End of Line Termination
Termination helps to ensure clean data signals are transmitted through the network 
wiring. Termination is applied to the end-of-line (EOL) HandPunch in the network 
daisy-chain. The factory default setting is for EOL termination to be disabled – 
switches 1 and 2 OFF. Refer to Figure 5-1 on page 22 for switch ON/OFF positioning.
To enable EOL termination at a HandPunch, both switches 1 and 2 must be ON.
To disable EOL termination at a HandPunch, both switches 1 and 2 must be OFF.
EOL Termination must be enabled for:
A single HandPunch terminal installation.
In a Modem to PC network the HandPunch terminal with the Modem option (for 
communication with the host computer).
5.2
Communication Method
The factory default setting and for standard operation, switch 3 must be OFF.
Switch 3 must always be OFF.
5.3
Erasing HandPunch Memory
The erase memory function can perform either or both of the following:
Erase a HandPunch’s configuration data.
Erase a HandPunch’s user database and transaction buffer.
The factory default setting (and normal operation setting) is for switches 4 and 5 to be 
OFF, retaining memory.
If the HandPunch is equipped with the battery backup option, remove shunt J7 in front 
of the DIP switch array (see Figure 4-1 on page 19) befor
e proceeding. Replace shunt 
J7 after completion of the following steps.
5.3.1
Erasing the HandPunch Setup
Perform the following steps to erase the configuration data but retain the user 
database.
1. With system power OFF, set switch 4 ON.
2. Turn system power ON and wait for HandPunch boot information to appear on the 
display.
3. Turn switch 4 OFF.
NOTE