The N-20AS and N-40AS add-on selectors are designed to function with the NEM Lamp Memory System, Type
"C" or later. Multiple add-on selectors can be added to a master station along with a variety of sub stations to
create a communication system tailored to a user's needs. All standard NEM system accessories can be used in
conjunction with the add-on selectors. Each add-on selector requires a dedicated 24V DC power supply.
"C" or later. Multiple add-on selectors can be added to a master station along with a variety of sub stations to
create a communication system tailored to a user's needs. All standard NEM system accessories can be used in
conjunction with the add-on selectors. Each add-on selector requires a dedicated 24V DC power supply.
n
Add-on Selectors for the NEM Lamp Memory System
N-20AS, 20-call N-40AS, 40-call
Pg. 1
NAMES & FUNCTIONS:
1. OFF button
2. Selector button
3. OFF LED
4. Directory card
5. Station selector LED
1. OFF button
2. Selector button
3. OFF LED
4. Directory card
5. Station selector LED
SPECIFICATIONS:
Power Source:
Power Source:
24V DC. Use PS-2420UL.
Communication Output: 500mW at 20 ohms
Communication:
Communication:
Push-to-talk, release-to-listen (TALK button), or VOX handset at master (handset models only).
Hands free at sub station.
Hands free at sub station.
All call output:
6W in a system of up to 20 sub stations
12W in a system between 21 and 40 stations.
12W in a system between 21 and 40 stations.
Calling:
Master to sub: By voice only after pretone.
Sub to master: Call button on sub activates tone and LED, remaining activated until answered.
Sub to master: Call button on sub activates tone and LED, remaining activated until answered.
Wiring:
2 conductors homerun to sub station, or loop multi-conductor cable with 1 common wire
plus 1 individual wire per sub station on the wire run.
Shielded cable is recommended. Use Aiphone #822202 (22AWG) or #821802 (18AWG) 2 cond.
Multiconductor: Aiphone #822210 (10 cond.), #822215 (15 cond.), #822220 (20 cond.)
plus 1 individual wire per sub station on the wire run.
Shielded cable is recommended. Use Aiphone #822202 (22AWG) or #821802 (18AWG) 2 cond.
Multiconductor: Aiphone #822210 (10 cond.), #822215 (15 cond.), #822220 (20 cond.)
Wiring Distance:
420' with 22AWG; 1,000' with 18AWG.
Individual Components for System:
NEM-n Master station (10, 20, 30, 40-call sizes)
NEM-nA
NEM-n Master station (10, 20, 30, 40-call sizes)
NEM-nA
Master station with handset (10, 20, 30, 40-call sizes)
NA-series
Any sub station with NA, NB, or NE model number prefix
PS-2420UL 24V DC, 2A Power Supply
Other Accessory items listed in catalog or price list as compatible with the NEM series.
Other Accessory items listed in catalog or price list as compatible with the NEM series.
1
2
5
4
3
N-nAS TERMINAL DEFINITIONS:
+
+
Positive 24V DC
-
Negative
1~40
Station number
E
Common communication
V1-V4 Connects to NB-U for
A1-A4 Background Music
A1-A4 Background Music